Hitachi HCP SNMP
Contenu du connecteur de supervision​
Objets supervisés​
Le connecteur de supervision Hitachi HCP SNMP inclut la supervision des Nodes, Tenants et Volumes.
Métriques collectées​
- Nodes
- Tenants
- Volumes
Metric name | Description | Unit |
---|---|---|
node status | Status of the node | |
nic status | Status of the nic | |
san path status | Status of the san path | |
bbu status | Status of the battery backup unit | |
nodeid#node.space.usage.bytes | Usage of the node | B |
nodeid#node.space.free.bytes | Free space left on the node | B |
nodeid#node.space.usage.percentage | Usage of the node in percentage | % |
nodeid#node.sensor.temperature.celsius | Sensor temperature | C |
nodeid#node.sensor.fan.speed.rpm | Sensor fan speed | rpm |
nodeid#node.sensor.voltage.volt | Sensor voltage | V |
It is possible to filter on the name of a node using a REGEXP of the form [--filter-node-id='101'
].
Metric name | Description | Unit |
---|---|---|
tenantname#tenant.space.usage.bytes | Usage of the tenant | B |
tenantname#tenant.space.free.bytes | Free space left on the tenant | B |
tenantname#tenant.space.usage.percentage | Usage of the tenant in percentage | % |
It is possible to filter on the ID of a tenant using a REGEXP of the form [--filter-tenant-name='backup'
].
Metric name | Description | Unit |
---|---|---|
volume status | Status of the volume | |
nodeid:label#volume.space.usage.bytes | Usage of the volume | B |
nodeid:label#volume.space.free.bytes | Free space left on the volume | B |
nodeid:label#volume.space.usage.percentage | Usage of the volume in percentage | % |
Prérequis​
Afin de contrôler vos équipements Hitachi HCP, le SNMP doit être configuré. (https://knowledge.hitachivantara.com/Documents/Storage/Content_Platform/9.0.x/Administering_HCP/System_monitoring/03_Configuring_SNMP)
Installation​
- Online License
- Offline License
- Installer le Plugin sur tous les Collecteurs Centreon :
yum install centreon-plugin-Hardware-Storage-Hitachi-Hcp-Snmp
- Sur l'interface Web de Centreon, installer le connecteur de supervision Hitachi HCP SNMP depuis la page Configuration > Gestionnaire de connecteurs de supervision
- Installer le Plugin sur tous les Collecteurs Centreon :
yum install centreon-plugin-Hardware-Storage-Hitachi-Hcp-Snmp
- Sur le serveur Central Centreon, installer le connecteur de supervision via le RPM:
yum install centreon-pack-hardware-storage-hitachi-hcp-snmp
- Sur l'interface Web de Centreon, installer le connecteur de supervision Hitachi HCP SNMP depuis la page Configuration > Gestionnaire de connecteurs de supervision
Configuration​
Ce connecteur de supervision est conçu de manière à avoir dans Centreon un hôte par équipement Hitachi HCP. Lorsque vous ajoutez un hôte à Centreon, appliquez-lui le modèle HW-Storage-Hitachi-Hcp-SNMP-custom. Il est nécessaire de remplir les valeurs des champs "SNMP Community" et "SNMP Version".
Si vous utilisez SNMP en version 3, vous devez configurer les paramètres spécifiques associés via la macro SNMPEXTRAOPTIONS. Plus d'informations dans la section Troubleshooting SNMP.
Mandatory | Name | Description |
---|---|---|
SNMPEXTRAOPTIONS | Extra options SNMP |
Par défaut, le modèle HW-Storage-Hitachi-Hcp-SNMP n'a pas de modèles de services associés. Vous pouvez au choix:
- associer des modèles de services au modèle d'hôte HW-Storage-Hitachi-Hcp-SNMP-custom
- utiliser la découverte des services
FAQ​
Comment faire le test en ligne de commande et que signifient les principales options ?​
Une fois le Plugin installé, vous pouvez tester celui-ci directement en ligne de commande depuis votre Collecteur Centreon avec l'utilisateur centreon-engine :
/usr/lib/centreon/plugins/centreon_hitachi_hcp_snmp.pl \
--plugin=storage::hitachi::hcp::snmp::plugin \
--mode=nodes \
--hostname=10.30.2.114 \
--snmp-version='2c' \
--snmp-community='hcp_ro' \
--filter-node-id='101' \
--warning-space-usage-prct='80' \
--critical-space-usage-prct='90' \
--verbose
Exemple de sortie :
OK: node '101' [ip address: 10.214.4.16] node status: available, nic status: ok, san path status: rain, battery backup unit status: Healthy - space usage total: 13.58 TB used: 350.93 GB (2.52%) free: 13.24 TB (97.48%) | '101#node.space.usage.bytes'=376806080512B;;;0;14933122809856 '101#node.space.free.bytes'=14556316729344B;;;0;14933122809856 '101#node.space.usage.percentage'=2.52%;0:80;0:90;0;100 '101~Temp_Ambient_FP#node.sensor.temperature.celsius'=25.0C;;;; '101~Temp_CPU0#node.sensor.temperature.celsius'=35.0C;;;; '101~Temp_CPU1#node.sensor.temperature.celsius'=40.0C;;;; '101~Temp_DIMM_AB#node.sensor.temperature.celsius'=28.0C;;;; '101~Temp_DIMM_EF#node.sensor.temperature.celsius'=29.0C;;;; '101~Temp_Outlet#node.sensor.temperature.celsius'=29.0C;;;; '101~Temp_PCH#node.sensor.temperature.celsius'=37.0C;;;; '101~Temp_PCI_Area#node.sensor.temperature.celsius'=33.0C;;;; '101~Temp_PCI_Inlet1#node.sensor.temperature.celsius'=30.0C;;;; '101~Temp_PCI_Inlet2#node.sensor.temperature.celsius'=28.0C;;;; '101~Temp_VR_CPU0#node.sensor.temperature.celsius'=27.0C;;;; '101~Temp_VR_CPU1#node.sensor.temperature.celsius'=32.0C;;;; '101~Temp_VR_DIMM_AB#node.sensor.temperature.celsius'=25.0C;;;; '101~Temp_VR_DIMM_CD#node.sensor.temperature.celsius'=27.0C;;;; '101~Temp_VR_DIMM_EF#node.sensor.temperature.celsius'=29.0C;;;; '101~Temp_VR_DIMM_GH#node.sensor.temperature.celsius'=31.0C;;;; '101~Fan_SYS0#node.sensor.fan.speed.rpm'=5100rpm;;;0; '101~Fan_SYS1#node.sensor.fan.speed.rpm'=4300rpm;;;0; '101~Fan_SYS2#node.sensor.fan.speed.rpm'=5100rpm;;;0; '101~Fan_SYS3#node.sensor.fan.speed.rpm'=4200rpm;;;0; '101~Fan_SYS4#node.sensor.fan.speed.rpm'=6600rpm;;;0; '101~Fan_SYS5#node.sensor.fan.speed.rpm'=5400rpm;;;0; '101~Fan_SYS6#node.sensor.fan.speed.rpm'=6500rpm;;;0; '101~Fan_SYS7#node.sensor.fan.speed.rpm'=5300rpm;;;0; '101~Volt_P12V#node.sensor.voltage.volt'=12.18V;;;; '101~Volt_P1V05#node.sensor.voltage.volt'=1.058V;;;; '101~Volt_P1V8_AUX#node.sensor.voltage.volt'=1.833V;;;; '101~Volt_P3V3#node.sensor.voltage.volt'=3.339V;;;; '101~Volt_P3V3_AUX#node.sensor.voltage.volt'=3.339V;;;; '101~Volt_P3V_BAT#node.sensor.voltage.volt'=3.161V;;;; '101~Volt_P5V#node.sensor.voltage.volt'=5.009V;;;; '101~Volt_P5V_AUX#node.sensor.voltage.volt'=5.009V;;;; '101~Volt_VR_CPU0#node.sensor.voltage.volt'=1.81V;;;; '101~Volt_VR_CPU1#node.sensor.voltage.volt'=1.81V;;;; '101~Volt_VR_DIMM_AB#node.sensor.voltage.volt'=1.22V;;;; '101~Volt_VR_DIMM_CD#node.sensor.voltage.volt'=1.22V;;;; '101~Volt_VR_DIMM_EF#node.sensor.voltage.volt'=1.22V;;;; '101~Volt_VR_DIMM_GH#node.sensor.voltage.volt'=1.22V;;;;
checking node '101' [ip address: 10.214.4.16]
node status: available, nic status: ok, san path status: rain, battery backup unit status: Healthy
space usage total: 13.58 TB used: 350.93 GB (2.52%) free: 13.24 TB (97.48%)
Cette commande contrôle les noeuds (--mode=nodes
) d'un équipement ayant pour adresse 10.30.2.114 (--hostname=10.30.2.114
)
en version 2c du protocol SNMP (--snmp-version='2c'
) et avec la communauté hcp_ro (--snmp-community='hcp_ro'
).
Cette commande déclenchera une alarme WARNING si l'utilisation de l'espace disque est supérieur à 80% (--warning-space-usage-prct='80'
)
et une alarme CRITICAL si supérieur à 90% (--critical-space-usage-prct='90'
).
Toutes les options qui peuvent être utilisées avec ce plugin se trouvent sur la commande --help
:
/usr/lib/centreon/plugins/centreon_hitachi_hcp_snmp.pl \
--plugin=storage::hitachi::hcp::snmp::plugin \
--mode=nodes \
--help
UNKNOWN: SNMP GET Request : Timeout​
Si vous obtenez ce message, cela signifie que vous ne parvenez pas à contacter l'équipement Hitachi HCP sur le port 161, ou alors que la communauté SNMP configurée n'est pas correcte. Il est également possible qu'un firewall bloque le flux.
UNKNOWN: SNMP GET Request : Cant get a single value.​
Si vous rencontrez cette erreur, il est probable que les autorisations données à l'agent SNMP soient trop restreintes.
- L'équipement Hitachi HCP ne prend pas en charge la MIB utilisée par le Plugin (branche: .1.3.6.1.4.1.116.5.46).
- L'OID SNMP ciblé ne peut pas être récupéré en raison de privilèges d'équipement insuffisants.