Aller au contenu principal

Hitachi HCP SNMP

Contenu du connecteur de supervision​

Objets supervisés​

Le connecteur de supervision Hitachi HCP SNMP inclut la supervision des Nodes, Tenants et Volumes.

Métriques collectées​

Metric nameDescriptionUnit
node statusStatus of the node
nic statusStatus of the nic
san path statusStatus of the san path
bbu statusStatus of the battery backup unit
nodeid#node.space.usage.bytesUsage of the nodeB
nodeid#node.space.free.bytesFree space left on the nodeB
nodeid#node.space.usage.percentageUsage of the node in percentage%
nodeid#node.sensor.temperature.celsiusSensor temperatureC
nodeid#node.sensor.fan.speed.rpmSensor fan speedrpm
nodeid#node.sensor.voltage.voltSensor voltageV

It is possible to filter on the name of a node using a REGEXP of the form [--filter-node-id='101'].

Prérequis​

Afin de contrôler vos équipements Hitachi HCP, le SNMP doit être configuré. (https://knowledge.hitachivantara.com/Documents/Storage/Content_Platform/9.0.x/Administering_HCP/System_monitoring/03_Configuring_SNMP)

Installation​

  1. Installer le Plugin sur tous les Collecteurs Centreon :
yum install centreon-plugin-Hardware-Storage-Hitachi-Hcp-Snmp
  1. Sur l'interface Web de Centreon, installer le connecteur de supervision Hitachi HCP SNMP depuis la page Configuration > Gestionnaire de connecteurs de supervision

Configuration​

Ce connecteur de supervision est conçu de manière à avoir dans Centreon un hôte par équipement Hitachi HCP. Lorsque vous ajoutez un hôte à Centreon, appliquez-lui le modèle HW-Storage-Hitachi-Hcp-SNMP-custom. Il est nécessaire de remplir les valeurs des champs "SNMP Community" et "SNMP Version".

Si vous utilisez SNMP en version 3, vous devez configurer les paramètres spécifiques associés via la macro SNMPEXTRAOPTIONS. Plus d'informations dans la section Troubleshooting SNMP.

MandatoryNameDescription
SNMPEXTRAOPTIONSExtra options SNMP

Par défaut, le modèle HW-Storage-Hitachi-Hcp-SNMP n'a pas de modèles de services associés. Vous pouvez au choix:

  • associer des modèles de services au modèle d'hôte HW-Storage-Hitachi-Hcp-SNMP-custom
  • utiliser la découverte des services

FAQ​

Comment faire le test en ligne de commande et que signifient les principales options ?​

Une fois le Plugin installé, vous pouvez tester celui-ci directement en ligne de commande depuis votre Collecteur Centreon avec l'utilisateur centreon-engine :

/usr/lib/centreon/plugins/centreon_hitachi_hcp_snmp.pl \
--plugin=storage::hitachi::hcp::snmp::plugin \
--mode=nodes \
--hostname=10.30.2.114 \
--snmp-version='2c' \
--snmp-community='hcp_ro' \
--filter-node-id='101' \
--warning-space-usage-prct='80' \
--critical-space-usage-prct='90' \
--verbose

Exemple de sortie :

OK: node '101' [ip address: 10.214.4.16] node status: available, nic status: ok, san path status: rain, battery backup unit status: Healthy - space usage total: 13.58 TB used: 350.93 GB (2.52%) free: 13.24 TB (97.48%) | '101#node.space.usage.bytes'=376806080512B;;;0;14933122809856 '101#node.space.free.bytes'=14556316729344B;;;0;14933122809856 '101#node.space.usage.percentage'=2.52%;0:80;0:90;0;100 '101~Temp_Ambient_FP#node.sensor.temperature.celsius'=25.0C;;;; '101~Temp_CPU0#node.sensor.temperature.celsius'=35.0C;;;; '101~Temp_CPU1#node.sensor.temperature.celsius'=40.0C;;;; '101~Temp_DIMM_AB#node.sensor.temperature.celsius'=28.0C;;;; '101~Temp_DIMM_EF#node.sensor.temperature.celsius'=29.0C;;;; '101~Temp_Outlet#node.sensor.temperature.celsius'=29.0C;;;; '101~Temp_PCH#node.sensor.temperature.celsius'=37.0C;;;; '101~Temp_PCI_Area#node.sensor.temperature.celsius'=33.0C;;;; '101~Temp_PCI_Inlet1#node.sensor.temperature.celsius'=30.0C;;;; '101~Temp_PCI_Inlet2#node.sensor.temperature.celsius'=28.0C;;;; '101~Temp_VR_CPU0#node.sensor.temperature.celsius'=27.0C;;;; '101~Temp_VR_CPU1#node.sensor.temperature.celsius'=32.0C;;;; '101~Temp_VR_DIMM_AB#node.sensor.temperature.celsius'=25.0C;;;; '101~Temp_VR_DIMM_CD#node.sensor.temperature.celsius'=27.0C;;;; '101~Temp_VR_DIMM_EF#node.sensor.temperature.celsius'=29.0C;;;; '101~Temp_VR_DIMM_GH#node.sensor.temperature.celsius'=31.0C;;;; '101~Fan_SYS0#node.sensor.fan.speed.rpm'=5100rpm;;;0; '101~Fan_SYS1#node.sensor.fan.speed.rpm'=4300rpm;;;0; '101~Fan_SYS2#node.sensor.fan.speed.rpm'=5100rpm;;;0; '101~Fan_SYS3#node.sensor.fan.speed.rpm'=4200rpm;;;0; '101~Fan_SYS4#node.sensor.fan.speed.rpm'=6600rpm;;;0; '101~Fan_SYS5#node.sensor.fan.speed.rpm'=5400rpm;;;0; '101~Fan_SYS6#node.sensor.fan.speed.rpm'=6500rpm;;;0; '101~Fan_SYS7#node.sensor.fan.speed.rpm'=5300rpm;;;0; '101~Volt_P12V#node.sensor.voltage.volt'=12.18V;;;; '101~Volt_P1V05#node.sensor.voltage.volt'=1.058V;;;; '101~Volt_P1V8_AUX#node.sensor.voltage.volt'=1.833V;;;; '101~Volt_P3V3#node.sensor.voltage.volt'=3.339V;;;; '101~Volt_P3V3_AUX#node.sensor.voltage.volt'=3.339V;;;; '101~Volt_P3V_BAT#node.sensor.voltage.volt'=3.161V;;;; '101~Volt_P5V#node.sensor.voltage.volt'=5.009V;;;; '101~Volt_P5V_AUX#node.sensor.voltage.volt'=5.009V;;;; '101~Volt_VR_CPU0#node.sensor.voltage.volt'=1.81V;;;; '101~Volt_VR_CPU1#node.sensor.voltage.volt'=1.81V;;;; '101~Volt_VR_DIMM_AB#node.sensor.voltage.volt'=1.22V;;;; '101~Volt_VR_DIMM_CD#node.sensor.voltage.volt'=1.22V;;;; '101~Volt_VR_DIMM_EF#node.sensor.voltage.volt'=1.22V;;;; '101~Volt_VR_DIMM_GH#node.sensor.voltage.volt'=1.22V;;;;
checking node '101' [ip address: 10.214.4.16]
node status: available, nic status: ok, san path status: rain, battery backup unit status: Healthy
space usage total: 13.58 TB used: 350.93 GB (2.52%) free: 13.24 TB (97.48%)

Cette commande contrôle les noeuds (--mode=nodes) d'un équipement ayant pour adresse 10.30.2.114 (--hostname=10.30.2.114) en version 2c du protocol SNMP (--snmp-version='2c') et avec la communauté hcp_ro (--snmp-community='hcp_ro').

Cette commande déclenchera une alarme WARNING si l'utilisation de l'espace disque est supérieur à 80% (--warning-space-usage-prct='80') et une alarme CRITICAL si supérieur à 90% (--critical-space-usage-prct='90').

Toutes les options qui peuvent être utilisées avec ce plugin se trouvent sur la commande --help :

/usr/lib/centreon/plugins/centreon_hitachi_hcp_snmp.pl \
--plugin=storage::hitachi::hcp::snmp::plugin \
--mode=nodes \
--help

UNKNOWN: SNMP GET Request : Timeout​

Si vous obtenez ce message, cela signifie que vous ne parvenez pas à contacter l'équipement Hitachi HCP sur le port 161, ou alors que la communauté SNMP configurée n'est pas correcte. Il est également possible qu'un firewall bloque le flux.

UNKNOWN: SNMP GET Request : Cant get a single value.​

Si vous rencontrez cette erreur, il est probable que les autorisations données à l'agent SNMP soient trop restreintes.

  • L'équipement Hitachi HCP ne prend pas en charge la MIB utilisée par le Plugin (branche: .1.3.6.1.4.1.116.5.46).
  • L'OID SNMP ciblé ne peut pas être récupéré en raison de privilèges d'équipement insuffisants.